1kV to 100kV, 5kW to 8kW

 

This series of power supplies can generate output that ranges from 1kV to 100kV, 5kW to 8kW and are housed in compact 19” racks to give a highly regulated output.

TECHNICAL SPECIFICATIONS

PARAMETER SPECIFICATION
Input Voltage 415V ±10% A C, 50Hz, three phase
Output Voltage Range* 1kV DC to 100kV DC
Output Power Range* 5kW to 8kW
Polarity* Positive / Negative
Line Regulation ≤0.1% for 10% variation in input voltage
Load Regulation ≤0.5% for 0 to 100% load variation
Ripple 0.5% rms at full rating
Stability Stability Better than 0.05%/hour after 1 hour warm up
Regulation Mode* Constant voltage – Constant current
Voltage & Current Control* Local: By 10-turn potentiometers on the front panel
Remote: 0 to 10V DC signals for voltage & current control; OR
Control through computer interface.
Remote Controls & Signals through Pluggable Connector
/ D-Connector (External RS232 Microcontroller Module) *
10V DC reference
10V DC HV enable signal
0 to 10V DC signal for voltage & current control
0 to 10V DC signal for voltage & current monitoring
Front Panel Three phase indicators
AC Power ON/OFF MCB
HV ON/OFF switch with indication
3½ digit voltage and current meters
10-turn potentiometers for voltage and current control
Constant voltage – constant current mode indication
LEDs for fault indications
Back Panel Terminal block for 3 phase input
Fuse holder(s) with fuse
Terminal for HV output with 10ft of detachable high voltage cable
Stud for grounding the unit
Remote interface connector*
Topology High frequency resonant / PWM-controlled switch mode
Switching Device IGBT
Cabinet 4U to 8U 19” rack, powder coated

*Optional. To be specified by the user.

Remote Interface Connector Configuration

Pins 28 Pin Pluggable Connector 25 Pin D Connector
1 Earth Earth
2 Common Common
3 Interlock HV Enable
4 HV Enable Voltage Control Remote
5 Reference Current Control Remote
6 Common Over Voltage Control Remote*
7 Voltage Control Remote Over Current Control Remote*
8 Voltage Control Local Common
9 Common Voltage Monitor
10 Current Control Remote Current Monitor
11 Current Control Local Reserved Monitor*
12 Common Reserved Monitor*
13 Voltage Monitor Common
14 Current Monitor Mode Status
15 Common* Interlock Status
16 Voltage Mode Status* HV ON Status
17 Current Mode Status* Common
18 HV ON Status* PS Fault Status*
19 Common* Over Voltage Status*
20 PS Fault Status* Over Current Status*
21 Over Voltage Status* Over Temperature Status*
22 Over Current Status* Open Circuit Status*
23 Over Temperature Status* Phase Failure Status*
24 Open Circuit Status* Reserved Status*
25 Phase Failure Status* Common
26 Common*
27 Over Voltage Control*
28 Over Current Control*

Ordering Code
HV 040 K 600 W N C I D 5 T

Ordering Code
HV 040 K
1
600 W N
2 3
C I D 5 T
5 6
Section Description Options Options Description
1 Output Voltage XXX Value of output voltage
2 Output Power Y Value of output power
3 Polarity
P
N
Positive
Negative
4 Short Circuit
A
B
C

D
Shut down
Shut down & manual reset
Shut down & automatic restart
Constant current
5 Regulation Mode
4
5

Constant voltage
Constant voltage & constant current
6 Control Mode
L
R

T

Local control
Remote control through D-connector
Remote control through pluggable connector

*Optional. To be specified by the user only as per application’s requirement.